Polling place accessibility: 4/136-146 Willoughby Rd (North Sydney)

Updated: 09 July 2020


Show:

Premises accessibility (Inspected 24 April 2019)
LocationCriteriaNotesAccessible
09 - Path of Travel
09 - Path of TravelIs the path lit adequately?Yes
09 - Path of TravelIs the path 1m wide on straight, 1.5m wide on curves?Yes
09 - Path of TravelIs the path firm and slip resistant?Yes
09 - Path of TravelIs the path free of lips greater than 3mm?Yes
09 - Path of TravelIs the path free of obstructions?Yes
09 - Path of TravelIs the path free of pot-holes, ridges, overgrowth and debris?Yes
09 - Path of TravelIs the path level?Yes
09 - Path of TravelIs the path obvious and likely to be used?Yes
10 - Path of Travel Steps
10 - Path of Travel StepsAre the steps constant in rise and tread?Yes
10 - Path of Travel StepsAre the steps in good condition?Yes
10 - Path of Travel StepsDo the steps have closed risers?No
10 - Path of Travel StepsDo the steps have contrasting nosings on each tread?No
10 - Path of Travel StepsDo the steps have secure handrails on both sides?No
10 - Path of Travel StepsNumber of steps1Yes
11 - Path of Travel Ramp
11 - Path of Travel RampAre there ramp landings at the top and bottom at least 1500mm long?Yes
11 - Path of Travel RampDoes the ramp have a suitable edge/kerb rail?No
11 - Path of Travel RampDoes the ramp have suitable handrails on both sides?No
11 - Path of Travel RampDoes the ramp have tactile indicators at the top and bottom?Yes
11 - Path of Travel RampIs the ramp accessible?No
11 - Path of Travel RampRamp gradient is 1 in5No
11 - Path of Travel RampRamp height200 mmYes
11 - Path of Travel RampRamp length1000 mmYes
12 - Building Entrance
12 - Building EntranceDoes the entrance area have adequate lighting?Yes
12 - Building EntranceIs external undercover queuing available for the entrance?Yes
12 - Building Entrance - Doorway
12 - Building Entrance - DoorwayDoorway opening width1800 mmYes
12 - Building Entrance - DoorwayIs the doorway/entrance covered and protected from rain?Yes
12 - Building Entrance - Threshold
12 - Building Entrance - ThresholdDoes the doorway/entrance have a threshold ramp?Yes
12 - Building Entrance - ThresholdIs the threshold ramp accessible?No
12 - Building Entrance - ThresholdRamp height70 mmNo
12 - Building Entrance - ThresholdRamp length120 mmYes
12 - Building Entrance - ThresholdThreshold ramp gradient is 1 in1.71No
13 - Entrance Steps
13 - Entrance StepsAre the steps constant in rise and tread?Yes
13 - Entrance StepsAre the steps in good condition?Yes
13 - Entrance StepsDo the steps have closed risers?No
13 - Entrance StepsDo the steps have contrasting nosings on each tread?No
13 - Entrance StepsDo the steps have secure handrails on both sides?No
13 - Entrance StepsNumber of steps1Yes
20 - Voting Area
20 - Voting AreaIs the floor surface even? Yes
20 - Voting AreaIs the floor surface slip-resistant?Yes
20 - Voting AreaIs the voting/activity area well lit for purpose?Yes
20 - Voting AreaWill there be at least 1.5 m free circulation space around obstacles?Yes
27 - Premises Furniture
27 - Premises FurnitureWill a disabled access voting screen be provided? Yes

This page last updated  28 May 2020